Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T09CM00801
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2009 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* DWV THRU ROOF WATER TEST OK PIPE WRAPS OK |
|
04/16/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* ALL DRAINAGE PIPING TO HAVE AT LEAST MINIMUM GRADE BACKPITCHED SECTIONS ARE NOT APPROVED CONTINUED "NOT READY" MAY RESULT IN REINSPECTION FEE |
|
04/14/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) CAPS ON DEMO PIPING UNDERGROUND OK 2) YOUR PIPE THRU CONNECTION AT OLD RESTROOM AREA AT EAST DOOR HAS BACK PITCH AND SO DOES YOUR CONNECTION TO EXISTING AT NEW RESTROOM AREA 3) PROVIDE MINIMUM 1/8" PER FOOT FALL ON 4" PIPING FOR DRAINAGE |