Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2011 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 09/20/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE HANDRAIL AT STAIRS 2) NO MORE THAN 4" SPHERE ALLOWED AT STAIR RAILS 3) BOND GAS LINE/COPPER WATER LINES 4) PROVIDE 90 DEGREE ELBOW AT TPR 5) COMPLETE LANDING AT FRONT DOOR 6) SEVERAL RECEPTS SHOWING OPEN GROUND THRU-OUT HOUSE 7) THUMB LATCH NEEDED AT W.I. DOORS-NO KEYED ALLOWED 8) COMPLETE UPPER DECK-DRYWALL AT GARAGE 9) SEAL ALL WATER CLOSETS AT BASE 10) NEED AIR ADMITTANCE VALVE AT KITCHEN 11) PROVIDE ADDRESS 12) EXT. GFCI NOT WORKING AND NEED PROPER BUBBLE COVERS 13) COMPLETE GRADING 14) GFCI'S AT KITCHEN-OPEN GROUND-REVERSE POLARITY 15) KITCHEN ISLAND OVER 6" COUNTER TO BASE NEEDS GFCI IN ACCESSIBLE PLACE |
|
| 08/10/2011 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* |