Permit: T09CM00776

Parcel: 141355580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T09CM00776

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/08/2009 FRAMING Approved IVRS - Inspection :*
06/05/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
PLEASE
1. LOOK AT ROOF TRUSSES MARKED WITH BLACK X, MISSING GUSSET PLATE OR PLATE ISN'T CENTERED NOT CONNECTING ALL 3 PIECES OF TRUSS
2. BANG PLATE LAST INSP.
06/03/2009 FRAMING Partial Approval IVRS - Inspection :*
1) 2ND FLOOR RECEPT TO BE ON AN APPROVED TYPE
2) ROOF TRUSSES STARTING ABOVE STAIRS, BOTTOM CHORD MARKED IN BLACK X, BOTTOM SIDE OF CORD DAMAGED, NOT CENTERED OVER JOINT OR MISSING METAL GUSSET PLATE
3) BANG PLATE ROMEX AT STUD WEST WALL 2ND FLOOR REAR BEDROOM
4) DRYER DUCT CONNECTION THRU TRUSS PIPE TO BE SAME SIZE THROUGHOUT