Permit: T09CM00728

Parcel: 103217170

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/15/2009 FRAMING Approved IVRS - Inspection :*
05/13/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEM #1 NOT MET. WILL REFEE AT THIS TIME
05/12/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER WALTER KOCH
05/07/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHASE AT BEDROOM NEEDS TO BE FIRE SEALED PER CODE R 602.1 2006 IRC
05/06/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO CUT OUT FOR CLEANOUT ON EXTERIOR LATH AT KITCHEN
2) NEED PROTECTION PLATES ON 1" SUPPLY (WATER) LINE AT GARAGE-TOP PLATE
3) NEED PITCH ON HVAC DRAIN LINE
4) NEED TO POUR SEAL SLAB AT HALL BATH TUB SHOE
5) MASTER BEDROOM CHASE NEEDS TO BE FIRE SEALED PROPERLY
6) NEED PROTECTION PLATE ON 2" VTR LINE AT LAUNDRY ROOM TOP PLATE
7) BLOCK AT BATHROOM FOR HANDICAP
8) WATER SUPPLY TEST WITH AIR MUST BE 50 PSI FOR 15 MINUTES (MINIMUM)