Permit: T09CM00728

Parcel: 103217170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/27/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/22/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FOLLOW NAIL PATTERN REQUIRED FOR EACH SIDE OF GARAGE 10/6 MSTA 49 REQUIRED ON INSIDE OF WALL
2) INCORRECT SIZES OF NAILS IN ALL P.A. STRAPS
3) PLAN CALLS FOR 2 X 8 ? AT AWNING
4) UNABLE TO LOCATE P.A. STRAP REQUIRED ON PLAN
5) CAN'T LOCATE DETAILS OR NOTES FOR INTERIOR SHEARWALLS IF ANY
04/20/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1. MINIMUM 2 ANCHOR BOLTS PER PLATE AT POSTS FOR PATIO
2. 2X8 - 2 FOR HEADER AT BACK PATIO DOOR
3. <B> 4' SHEAR PANELS AT CORNERS
4. TRIPLE PLATE OVERHEAD DOOR WALLS
5. FRONT AWNING TO PLANS
6. STOPPED INSPECTION