Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09CM00683
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/22/2009 | PLUMBING - FINAL | Not ready for Inspection | DOOR LOCKED -- NO ACCESS | |
| 06/11/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* SECURE FOOD PREP SINK SUPPORT DRAIN FROM SODA COMPLETE PREVIOUSLY NOTED REQUIREMENTS |
|
| 06/09/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. RED LINE CHANGES AT FOOD PREP/HS 2. PERM CAP UNUSED DRAINS 3. PROVIDE PROPER INSTALLATION OF INDIRECT WASTE PIPING I.E. CLEANOUTS, P-TRAP OVER 5' 4. PROVIDE SUPPORT & 1" AG, W/NO SPLASHING AT FS GRATE 5. CORRECT DIRECTION OF FLOW AT FLOW CONTROL AND VENT TAKE OFF 6. PROVIDE STERILIZATION REPORT 7. PROVIDE EXPANSION TANK & VACUUM RELIEF VALVE AT WH |