Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM00680

Parcel: 141316570


Addresses:

7841 E TREETOP RD


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM00680

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/01/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/27/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO COVER ALL EXT. WALLS
2) QUEST. SHEAR TRANSFER AT GARAGE TO HOUSE WALL, WILL CHECK AT INTERMEDIATE INSPECTION
05/21/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) #9 SHEARWALL 4" ON CENTER
2) NEED 4, 16D'S AT GARAGE HIP JACKS TOP CHORD (LOAD)
3) X BRACES AT MAIN GABLE TO GO TO PEAK OF ROOF
4) GARAGE, SHEAR BOTH SIDES, FRONT EDGES 3" ON CENTER
5) DBL 2 X 10 REQUIRED AT FRONT PORCH, TRUSS DRAWING SHOWS FULL BEARING
6) TIE SHEARWALL GARAGE TO HOUSE 6/SD3 OK
05/20/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NEED A S1 PLAN
2) NOTE: CHECK CONTINOUS BEARING C06G/E AT ENTRY BEAM ?