Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/06/2009 | ENGINEERING - FINAL | Approved | ||
| 05/05/2009 | ENGINEERING - FINAL | Correction Required | CHECKED FORMS FOR RAMP AT N SIDE OF BUILDING SLOPE IS VERY CLOSE TO MAX 8.33% CONTRACTOR TO ADJUST BEFORE POURING CONCRETE |
|
| 04/30/2009 | ENGINEERING - FINAL | Correction Required | NEW SIDEWALK ON SW CORNER OF BUILDING IS OUT OF ADA COMPLIANCE CROSS SLOPE WAS 4% OR GREATER IN SOME LOCATIONS NOTIFIED CONTRACTOR AND OWNER |
|
| 04/16/2009 | ENGINEERING - FINAL | Correction Required | VERIFIED CROSS SLOPE OF SIDEWALK AT WEST SIDE OF BUILDING TO BE FORMED AT LESS THAN 2% CROSS SLOPE TALKED TO YOUTH PASTOR REGARDING ACCESSIBLE RAMP IN COURTYARD AREA. THE HAND RAILS MUST HAVE TURNED DOWN ENDS AT N AND S ENDS OF RAIL EITHER SIDE OF RAMP TO BE IN COMPLIANCE UNABLE TO LOCATE ACTIVITY NUMBER FOR ERIK HITE PARK ADDITION |
|
| 04/09/2009 | ENGINEERING - FINAL | Correction Required | ADDED C OF O INSPECTION FOR ADA SITE WORK DONE STILL ONE OUTSTANDING PERMIT T06CM01455 FOR THIS SITE NOT APPROVED BY FIRE/BLDG FINAL OR ENGINEERING |