Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09CM00643
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) INSPECTIONS WERE FOR THE 4 UNIT TW0 STORY LOCATED IN THE SW CORNER. ORIGINALLY ID'D AS UNITS A,B,C AND D ARE NOW 5,6,7 & 8 |
|
| 08/21/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLEX NOT ALLOWED ON T & P 2) PROVIDE CORRECT INSTALLATION ON SINGLE WALL VENT PIPE 3) USE PROPER TOOL FOR THIS INSTALLATION 4) PROVIDE CORRECT DIRECTION OF FLOW |
|
| 08/14/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CORRECTIONS IN UNIT #8 ON STARS ON RIGHT OK 2) UNIT 5 CORRECT VENT CONNECTOR, SLOPE AND PROPOSE DIRECTION OF FITTINGS 3) CHECK T & P, REPLACE IF DRIPPING 4) UNIT #6 NEW WH REQUIRES CORRECT VENTING AND T & P TERMINATION |
|
| 07/28/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) UNIT #7-NO WORK HAS BEEN DONE IN UNIT #7 2) NO GAS CLEARANCE IS REQUIRED AT THIS TIME |
|
| 07/16/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) #8 PROVIDE LISTED VENT INCREASER AND SECURE WITH SCREWS 2) FERNCO COUPLINGS NOT ALLOWED IN BLDG. PROVIDE LISTED TRANSITION COUPLINGS |
|
| 06/09/2009 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* UNIT FIRE FINAL OK |
|
| 06/08/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CAULK HOLE IN EXTERIOR WALL 2. ONLY ONE SLIP NUT ALLOWED ON DISCHARGE SIDE OF P-TRAP REASSEMBLE WATER CLOSET |
|
| 06/02/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* I DON'T KNOW WHAT YOU WANT INSPECTED NO CHANGE IN UNIT #5 FROM YESTERDAY PLEASE LEAVE A NAME AND CONTACT NUMBER WHEN SCHEDULING INSPECTIONS. |
|
| 06/01/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. VENT CONNECTOR REQUIRES 3 SHEET METAL SCREWS AT EACH JOINT 2. RUN T&P RELIEF DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL 3. PLUG OFF END OF STOVE FLEX 4. KITCHEN SINK NOT CAULKED 5. POINT OF VENT MAY NOT BE BELOW TRAP WEIR RUBBER 90 DEG. NOT APPROVED 6. SUPPORT GAS PIPING ON THE WALL UNIT #5 ONLY |
|
| 04/16/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PLEASE POST YOUR UNIT NUMBERS ACCORDING TO YOUR PERMIT -- UNABLE TO LOCATE 05, 06, 07, 08 |
|
| 04/09/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HAVE YOUR PERMIT CHANGED TO REFLECT CORRECT ADDRESS FOR INSPECTION AND PROVIDE ACCESS AT REINSPECTION. NO ACCESS. |
|
| 04/07/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CALLED 623-1077 AND LEFT MESSAGE TO MAKE CONTACT WITH ME. UNITS ARE OCCUPIED AND NO ACCESS TO ALL UNITS GAS IS CURRENTLY ON TO ALL UNITS. PLEASE MAKE CONTACT AND PROVIDE ACCESS INFORMATION ABOUT THIS PROJECT. CONTACT:BOB RICH @ 240-0248 |