Permit: T09CM00635

Parcel: 12901058A


Addresses:

624 S TUCSON BL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/21/2010 FRAMING Approved IVRS - Inspection :*
05/20/2010 FRAMING Cancelled IVRS - RI canceled
05/20/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP ALL FURR DOWNS
2) USE FAN APPROVED BOXES
3) GROUND ALL METAL BOXES
4) ALLOW GROUND WIRE TO CONNECT TO DBL SWITCHES
5) PLUG EXTRA HOLES ON METAL BOXES
03/26/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
BASEMENT:
1) MISSING OUTLET PER PLAN
2) ALL LUMBER TOUCHING CONCRETE SHALL BE TREATED
1ST FLOOR:
1) GROUND ALL METAL BOXES
2) MISSING OUTLETS PER CODE LIVING ROOM
3) HARDWIRED SMOKE ALARMS INTERCONNECTED
4) PROVIDE APPROVED CEILING FOR BOXES EACH BEDROOM AND HALLWAYS
5) MISSING OUTLETS PER CODE KITCHEN-PROVIDE 2-20 AMP SMALL APPLIANCE CIRCUITS MICROWAVE AND REFRIDGE INDEPENDENT CIRCUITS
6) EXT. LIGHT FIXTURES EXIT DOOR SWITCHED UPSTAIRS
7) GROUND METAL BOXES
8) SMOKE ALARM
9) NAIL PROTECT THROUGHOUT
10) CHECK BOOT SIZES THROUGHOUT
11) BLOCK BOOTS 3 SIDES THRU-OUTN
01/29/2010 FRAMING Not ready for Inspection IVRS - Inspection :*