Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T09CM00583
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/11/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection WATER TEST FOR INDIRECT WASTE FOR CAST EQUIPMENT COUNTER OK 1. END OF LINE C/O TO BE ACCESSIBLE. NOTE: BACKFLOW PROTECTION DEVICES MAY BE INTERFERING WITH ELECTRIC OUTLETS, CHECK WITH ELECTRICAL INSPECTOR, 2" DRAIN ARMS REQUIRE 2" P-TRAPS. INDIRECT DRAINS REQUIRE MINIMUM OF 1" AIR GAPS. |
|
| 02/03/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CONSULT ABOUT INDIRECT DRAINAGE FOR MACHINES ONLY |
|
| 12/30/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 12/28/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) THIS INSPECTION FOR GREASE TRAP TO BLDG SEWER CONNECTION WATER TEST OK |
|
| 12/23/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
| 12/22/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV THRU ROOF WATER TEST AND WATER DIST. OK 2) DISCHARGE OF INTERCEPTOR TO HAVE EXTERNAL TRAP 3) NEED TO SEE ALL FLOOR SINKS AND DRAINS INSTALL |
|
| 12/21/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) TEST TO HOLD WITH NO LEAKS 2) PROVIDE LING RADIUS FITTINGS FOR HORIZONTAL X HORIZONTAL 3) PROVIDE BCK ROOF SUPPORT FOR CARRIER |