Permit: T09CM00556

Parcel: 110113620

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/14/2009 PLUMBING - FINAL Approved
05/13/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM 1" AG AT SANITIZER COMPARTMENT
2) ONLY ONE P TRAP PER TRAP ARM ALSO TRAP AND TRAP ARM OT BE THE SAME SIZE
3) PROVIDE UNIONS ON WH CONNECTIONS
05/12/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE MIXING VALVE AT LAV-1
2. PROVIDE MEANS FOR WATER HAMMERING AT WASHER
3. PROVIDE CHLORINATION REPORT
4. LIST MAY NOT BE COMPLETE