Permit: T09CM00549

Parcel: 136190270


Addresses:

3410 S TAHOE DR

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
06/25/2009 BUILDING - PROGRESS Approved IVRS - Inspection :*
04/02/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHOT PINS NOT APPROVED FOR UPLIFT
2) NEED MECHANICAL TIE (BOTTOM PLATE STUD) TOP PLATE TO STUD, ALL COLUMNS
03/12/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED SECURE CONNECTION OF BRICK POSTS TO BEAM
2) FILL ALL HOLES IN H2.5 CLIPS WITH JOIST HANGER NAILS
3) EXPOSE AT LEAST ONE FRONT COLUMN FOR INSPECTION. IF PROPERLY SECURED, OK. OTHERWISE EXPOSE ALL COLUMNS AND SECURE APPROPRIATELY
4) SET BACKS TO PLOT PLAN OK