Permit: T09CM00477

Parcel: 12418243A


Addresses:

1331 E 21ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/09/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
25 PSI TEST OK
LEFT GAS CARD
03/18/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
REMOVE TEE ON PIPING.
FUTURE OUTLET ALLOWED ONLY IF SHOWN ON PLAN
USE PIPE CLAMPS NOT CONDUIT CLAMPS

NOTE: CODE REQUIRES 1/10 PSI INCREMENTATIONS
ON TEST GAUGE

ALSO, PROVIDE ELECTRICAL BONDING OF GAS LINE.

NOTE: IT APPEARS THAT YOUR ELECTRICAL PANEL IS MISSING THE GROUND WIRES