Permit: T09CM00451

Parcel: 125081000


Addresses:

2419 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09CM00451

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/09/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
PLUMBING FINAL OK
THIS INSPECTION IS FOR ICE MACHINE ONLY
03/06/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CORRECT BACKPITCH ON ICE BIN DRAIN
REMOVE IN LINE VENT ON DRAIN (VENT NOT REQUIRED UNLESS OVER 15')
2. REQUIRE MINIMUM 1" AIR GAP AT FLOOR SINK
3. TRAP TO BE SET TRUE
03/03/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE SEPARATE CONDENSATE AND BIN STORAGE DRAINS, WITH P-TRAPS IF OVER 5' IN LENGTH OF APPROVED PRIMED THEN GLUED PVC IF USED, GRAVITY DRAIN TO APPROVED RECEPTOR WITH 1" AIR GAP AS REQUIRED PROPERLY SUPPORTED AND SECURED
2. PROVIDE PROOF OF 1" AIR GAP FOR WATER INLET OR APPROVED BACKFLOW DEVICE WITH CERTIFICATION IF REQUIRED OR LISTING OF PROOF OF CORRECT WATER INLET FOR THIS USE.

(THIS INSPECTION FOR ICE MACHINE ONLY)