Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROOF DRAINS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2010 | PLUMBING - ROOF DRAINS | Approved | IVRS - Inspection :* | |
| 03/26/2010 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) CHANGES OF DIRECTION ON RWL, CLAMPING RINGS, CLAMP RISERS UPC 1101.3, 706, 707.5 2) TEST UN OVERFLOWS AND CENTER DRAINS OK 3) GAS PIPING IN BLDG WITH 10.5 PSI TEST OK |