Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2009 | BUILDING - FINAL | Approved | ||
| 10/07/2009 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) EXPOSE 1 SIDE OF LARGE OPENING SO I CAN SEE HEADER AND CONNECTION 2) NEED TO SIZE HEADER AND BEAM 3) EMERGENCY ESCAPE OPENINGS TO HAVE MINIMUM CLEAR WIDTH OF 20". BEDROOM REPLACEMENT WINDOWS DO NOT QUALIFY AND MUST BE REPLACED 4) YOU MAY NOT HAVE EXPOSED FOAM OR KRAFT PAPER EXOSED IN ATTIC AREA |
|
| 10/05/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXISTING BEDROOM WINDOWS HAVE BEEN CHANGED DUE NOT MEET EGRESS 5.7 SQ NOT OPENING 2) NEW MECH SYSTEM ENTIRE HOME 3) COMPLY WITH PREVIOUS NOTES 1 & 2 |