| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2009 | BUILDING - FINAL | Approved | ||
| 09/04/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ? WALL SCREWS ARE NOT FOR WOOD CONNECTORS |
|
| 06/30/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LABEL RECEPTACLES AT COOLER DISCONNECT 2) 5J ELECTRIC CABLE IS NOT ALLOWED FOR BRANCH CIRCUITS 3) WOOD IN CONTACT WITH EARTH MUST BE PROPERLY TREATED (ITEM 1 ABOVE) 4) PLEASE READ PREVIOUS CORRECTION LIST (2 ABOVE) 5) SCREEN REQUIRED FOR ATTIC VENTS (1/8"-1/4" MESH) 6) FRONT GABLE VENT REQUIRED 7) FINISH SHEETROCK 8) YOU MAY NOT HAVE THE KRAFT PAPER ON INSULATION EXPOSED IN A CONCEALED SPACE |
|
| 06/17/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REPAIR COOLER STAND (MAKE STRUCTURALLY SOUND) 2. SUPPORT WATER SUPPLY TO COOLER PER UPC 3. PROVIDE CORRECT DISCONNECTS/FUSING/WIRING TYPE FOR COOLER 4. REPLACE GABLE END VENTS; INSULATION FOR CEILINGS CEILINGS COVERINGS 5. BEDROOM WINDOWS MUST BE OPERABLE 6. TPRV DISCHARGE LINE REQUIRED ON WATER HEATER 7. LABEL DISCONNECTS @ SUB-PANEL |