Permit: T09CM00423

Parcel: 113052560

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM00423

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/18/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
A WOOD SHIM IS NOT AN APPROVED SUPPORT AFTER INSTALLING LISTED SUPPORT, OK TO COVER FLOOR & WALLS
03/16/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
YOU HAVE A COUPLING W/IMPROPER ALIGNMENT
THAT IS CREATING A SHORT SECTION W/BACK PITCH
03/13/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE MIN. 1/4" PER FOOT SLOPE, CORRECT BACKPITCH AT COUPLING. RETEST. OK TO COVER FRONT SIDE OF WALL ONLY IF BACKSLIDE IS ACCESSIBLE USE APPROVED TRANSITION COUPLING AT REVENT.
03/11/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
YOU MAY NOT DUMP A WASTE LINE INTO A VENT