Permit: T09CM00412

Parcel: 141313580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T09CM00412

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/12/2009 FRAMING Approved IVRS - Inspection :*
05/11/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER JOHN
05/07/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE TO HOUSE WALL NAIL STUDS TO OSB, AT EACH H.D.
2) MISSING NAILING SHEARWALL INTERIOR
3) 2ND FLOOR SHOWER (MSTR) DIVERTER STUD (OVER NOTCHED). ADD FHA STRAP
4) MOVE 2 X 6 VERT BACKING OVER, AT 2ND FLOOR TUB SURROUND
5) NAIL BLOCKS (LADDER) 2ND FLOOR SHEAR TRANSFER TO TOP PLATE
6) NEED 3 1/8 X 10 GLU LAM AT 3 BAY GARAGE, NOT DBL 2 X 8
7) MISSING BACKING AT FLANGE TUB SURROUND 1ST FLOOR, BROKEN STUD