Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM00411

Parcel: 141313570

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM00411

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/24/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/20/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1. BROKEN TRUSS WEB, FRONT LIV. ROOM
2. NAILS SIZE FOR HANGERS LSSU210 #10 COMMON,
8s USED 821 LBS.
3. (DG21) TRUSS WEB BRACING
4. BETWEEN FLR TRUSSES LIV. LENGTH OF SHEAR BLK/NG PANELS
5. CHECK HANGER LOAD 821 LBS.
6. CRIPPLE UNDER HEADER ACROSS STAIRS (BETWEEN FLRS)
7. #1 SHEAR WALL TRANSITION FROM OSB TO SHEETROCK NAIL BOTH, EDGES OSB SHEETROCK

(WALKED ROOF OK)