Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM00411
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/20/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1. BROKEN TRUSS WEB, FRONT LIV. ROOM 2. NAILS SIZE FOR HANGERS LSSU210 #10 COMMON, 8s USED 821 LBS. 3. (DG21) TRUSS WEB BRACING 4. BETWEEN FLR TRUSSES LIV. LENGTH OF SHEAR BLK/NG PANELS 5. CHECK HANGER LOAD 821 LBS. 6. CRIPPLE UNDER HEADER ACROSS STAIRS (BETWEEN FLRS) 7. #1 SHEAR WALL TRANSITION FROM OSB TO SHEETROCK NAIL BOTH, EDGES OSB SHEETROCK (WALKED ROOF OK) |