Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09CM00408

Parcel: 13315062F

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
04/01/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/11/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
DWV W/TEST THRU ROOF OK
OK TO BACKFILL
03/10/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. NO TEST ON SYSTEM
2. CALL FOR BOTH ROUGH AND INTERMEDIATE INSPECTIONS
3. PROVIDE LADDER FOR ABOVE CEILING INSP.
PROVIDE SLOPE, SUPPORT AND PROTECT TRAP ARMS PASSING THRU METAL.
4. WRAP ABS PASSING THRU CONCRETE
5. RELOCATE T&P AND INSTALL BACKING AT MS FAUCET
6. LAV CARRIER SPECIFIED
7. SAFETY PLATES MISSING
8. ISOLATE AND PROTECT COPPER
9. OK TO INSULATE HW PIPING
10. CLOSET STUB IS TOO LOW (DRAIN)