Permit: T09CM00384

Parcel: 107030550


Addresses:

1966 W GRANT RD

Inspection Status: Denied

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
08/06/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
LAUNDRY ROOM:
1) EXTEND WH PRESSURE RELIEF LINE TO EXTERIOR
2) PROTECT ROMEX IN LAUNDRY UNDER 8' FROM PHYSICAL DAMAGE
3) SECURE ROMEX 8" FROM BOXES INSULATION MUST TERMINATE 1/4" INTO BOX
4) PROVIDE COMBUSTION RELIEF TO EXTERIOR
5) OMIT SPLICED WIRE AT SWITCH
ARIZONA ROOM:
1) PER CODE REQUIRES HEATER IN ROOM HARD WIRED
2) PROVIDE SWITCHED FIXTURE TO EXIT DOOR
3) EXPOSED WIRING INTERIOR FIXTURE