Permit: T09CM00351

Parcel: 11706089A


Addresses:

345 E TOOLE AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09CM00351

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/27/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
08/26/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PER P-4 INSTALLATION INSTRUCTIONS ON PLAN. PROVIDE A NON-SLAM CHECK VALVE FOR BY PASS
08/25/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE 90 DEGREE DOWN ON 1ST LEVEL T & P DRAIN TERMINATION
2) SECURE AND SUPPORT EXPANSION TANK AT BOOSTER PUMP
3) WHERE IS THE PRESSURE TANK AND SUCTION. CHECK VALVE AND PRESSURE RELIEF ON BOOSTER SYSTEM PER PLAN ?
4) PROVIDE LISTING FOR R.O. SYSTEM FOR DIRECT SANITARY DRAIN CONNECTION WITH NO AIR GAP FAUCET
5) COMPLETE INSULATION ON 2ND AND 3RD LEVEL HOT AND HOT RETURN PIPING
6) INSTALL WATER HEATER PIPING PER PLAN (ADDITIONAL CHECK VALVE)
08/19/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SHOWER PAN OK