Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T09CM00321

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/24/2009 FRAMING Approved IVRS - Inspection :*
03/19/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOT ENOUGH AIR PRESSURE FOR PLUMBING DWV TEST
2) NEED PROTECTION PLATES ON ELECTRICAL CIRCUIT WHEN LESS THAN 1 1/4" TO EDGE OF PLATE OR STUB MATERIAL
3) NEED A35 CONNECTION ON NORTH WALL PER PLAN
4) DID YOU DELETE FURRED OUT WALL ON EAST SIDE OF BATHROOM, NEED TO RED LINE
5) CONNECTION FOR LEDGER (2 X 6) TO ADOBE WALL ONLY
6) NEED FIRE SEAL OPENING INTO DROP WHERE DRYWALL WILL NOT COVER