Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T09CM00321
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2009 | FRAMING | Approved | IVRS - Inspection :* | |
03/19/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT ENOUGH AIR PRESSURE FOR PLUMBING DWV TEST 2) NEED PROTECTION PLATES ON ELECTRICAL CIRCUIT WHEN LESS THAN 1 1/4" TO EDGE OF PLATE OR STUB MATERIAL 3) NEED A35 CONNECTION ON NORTH WALL PER PLAN 4) DID YOU DELETE FURRED OUT WALL ON EAST SIDE OF BATHROOM, NEED TO RED LINE 5) CONNECTION FOR LEDGER (2 X 6) TO ADOBE WALL ONLY 6) NEED FIRE SEAL OPENING INTO DROP WHERE DRYWALL WILL NOT COVER |