Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T09CM00303
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* BLDG "A" UNITS 13, 14, 15, 16 - TUBS OK |
|
| 03/10/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER FLOOR & CEILING 2. OK TO COVER WALLS EXCEPT BEHIND TUB DRAIN CONN. 3. RECALL FOR INSPECTION & TEST AFTER INSTALLING TUBS 4. PLEASE ADD BUILDING A TO UNIT DESIGNATION |
|
| 03/06/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. WORK NOT COMPLETE 2. NEED TO SUPPORT TUB DRAIN ABOVE CEILING AND I NEED TO INSPECT THE DRAIN PIPING AND CONN. TO TUB WITH A RUN TEST PRIOR TO CONCEALMENT. 3. INSTALL TEMPORARY PLUGS IN ALL DRAIN PIPING DURING CONSTRUCTION TO PREVENT THE ESCAPE OF SEWER GASSES (TAPE IS NOT ACCEPTABLE) 4. CAP SOFT CU WATER LINES IN WALL BEFORE SETTING TUB 5. STRAP PEX NEAR SHOWER VALVE |