Permit: T09CM00303

Parcel: 12511201A


Addresses:

3660 E 3RD ST #13


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM00303

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/17/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
BLDG "A" UNITS 13, 14, 15, 16 - TUBS OK
03/10/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO COVER FLOOR & CEILING
2. OK TO COVER WALLS EXCEPT BEHIND TUB DRAIN CONN.
3. RECALL FOR INSPECTION & TEST AFTER INSTALLING TUBS
4. PLEASE ADD BUILDING A TO UNIT DESIGNATION
03/06/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. WORK NOT COMPLETE
2. NEED TO SUPPORT TUB DRAIN ABOVE CEILING AND I NEED TO INSPECT THE DRAIN PIPING AND CONN. TO TUB WITH A RUN TEST PRIOR TO CONCEALMENT.
3. INSTALL TEMPORARY PLUGS IN ALL DRAIN PIPING DURING CONSTRUCTION TO PREVENT THE ESCAPE OF SEWER GASSES (TAPE IS NOT ACCEPTABLE)
4. CAP SOFT CU WATER LINES IN WALL BEFORE SETTING TUB
5. STRAP PEX NEAR SHOWER VALVE