| 07/26/2010 | PLUMBING - ROOF DRAINS | Approved | IVRS - Inspection :* 1) VERTICAL BY HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 1) OK TO COVER 1) POST YOUR ADDRESS 2) PROVIDE A STAMPED LETTER ALLOWING BLDG DRAIN MATERIAL-PVC STAMPED DWV ONLY |
|
| 07/07/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* 1) DRAINS NOT INSTALLED PER PLAN |
|
| 06/11/2010 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) WATER TEST RAIN DRAINS AND OVERFLOW RAIN DRAINS PER RED LINES ON SITE PER RFI'S #5 & #28 CHANGE IN SIZING REQUIRES PLAN CHECK REVISION WITH VERIFICATION OF PERCENT OF FALL ON 4" PIPING 4" AT 1/8" PER FT=2506 SQ FT AND 4" AT 1/4" PER FT=3533 SQ FT |