Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T09CM00261
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2010 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 01/07/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT STORE FRONT |
|
| 01/04/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT STORE FRONT |
|
| 12/17/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) LOADING DECK OK |
|
| 12/15/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT FRONT COLUMNS |
|
| 12/11/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 16' LIFT AT LOADING DOCK |
|
| 12/10/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 12' LIFT AT LOADING DOCK, PROGRESS ONE COLUMN |
|
| 12/09/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) MISSING REBAR |
|
| 12/07/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 8' LIFT EAST WALLS, TOP OUT WEST WALL STORE FRONT SOUTH HALF |
|
| 12/03/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LOADING DOCK AREA GL" 6/B-C @ 48" affe gl: 6/C.5 @ 21' (TOPPED OUT); 4 COLUMNS @ 48" GL 0.1/A.2-D5; 1 COLUMN @6'8" GL 0.1/B.5 OK TO GROUT PROGRESS AREAS |
|
| 12/01/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SITE WALL AT 4'-8' AFFE; GL: 1/C.5-D.75-OK TO GROUT PROGRESS AREAS |
|
| 11/25/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALL AT G.L. 1.1/E-C.5 AT 4'; COLUMN AT G.L. B.6-0.1 OK TO GROUT PROGRESS AREAS |
|
| 11/24/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16' LIFT GL 7/A-C |
|
| 11/20/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALL AT 17' 4" LINE C.5/6-7; LINE 1.1/E-C.5 (STEM WALL) COLUMN B.6-0.1 PIER DETAIL #19 PAGE A.60-OK TO GROUT PROGRESS AREAS |
|
| 11/18/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 12' LIFT SHIPPING AND RECEIVING ROOM |
|
| 11/16/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 12' LIFT SOUTHEAST CORNER |
|
| 11/13/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 8' LIFT 30" FROM SOUTH CORNER 6' LIFT AT LOADING DOCK |
|
| 11/10/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) PROGRESS AREA GL C/6-7 AND 7/B.8-C |
|
| 11/06/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT GL 1-7/A |
|
| 11/04/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16'-17' 4" A/1-7 |
|
| 11/02/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16' LIFT 1-7/A |
|
| 10/28/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 3RD LIFT GL 1-7/A 1ST LIFT 30' SOUTH EAST CORNER |
|
| 10/26/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT GL 1-7/A |
|
| 10/22/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GRID LINE E/6-C/6-OK TO GROUT |
|
| 09/22/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) IN BEDS FOR GIRDERS ON SOUTH WALL |