Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T09CM00249
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2011 | FRAMING | Approved | IVRS - Inspection :* | |
11/12/2010 | FRAMING | Partial Approval | IVRS - Inspection :*. 1) RC CHANNEL IN ROOMS #112 THRU #117 OK TO COVER |
|
11/10/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) RC CHANNEL AND DROPS #109,102,101,110,119,118,111 AND 112 |
|
11/04/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) STAMPED RFI ELIMINATING KITCHEN DROP 2) 2ND FLOOR COMMUNITY ROOM DROP AND CEILING FRAMING |
|
11/03/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED RFI CHANGE IN SOFFIT |
|
10/13/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO HANG 2ND FLOOR BATH DROP LIDS WITH TRADE INSPECTORS OK |
|
10/12/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 1ST FLOOR FIRE STOP |
|
10/05/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEEDS FIRE CAULKING AT TOP AND BOTTOM PLATE |
|
10/04/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) INSTALL MISSING H3 ANCHORS AND NAILS IN SHEAR STRAPPING |
|
10/01/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 1ST FLOOR COMPLETE-OK TO COVER |
|
09/23/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR CORRIDOR |
|
09/17/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) LIVING UNITS-BATHROOMS IN BATH/SHOWER AREAS-OK TO INSULATE AND SHEETROCK |
|
09/16/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SHEAR PANELS-STRAPS AS PER PLANS OK TO COVER EXTERIOR WALLS |
|
09/14/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
09/08/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
09/08/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SHEAR, CLIPS, STRAPPING AND SHEATHING AT NORTH AND SOUTH STAIR TOWERS BOTH FLOORS-OK TO COVER |
|
09/02/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR DECKING COMPLETE OK |
|
09/01/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2ND LEVEL SUB FLOOR (NEXT SECTION NORTH AS MARKED) |
|
08/31/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
08/30/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2ND LEVEL SUB FLOOR (SOUTH 1/3 AS MARKED) |