Permit: T09CM00222

Parcel: 107030630


Addresses:

1941 W SPRING ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/10/2009 FRAMING Approved IVRS - Inspection :*
08/24/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) EXPOSE GAS LINE
2) OK TO SHEETROCK INTERIOR
08/04/2009 FRAMING Partial Approval IVRS - Inspection :*
1) 12-2 AND 14-2 WIRING MADE UP IN SAME BOX THROUGHOUT LAUNDRY
2) ROMEX CONNECTOR BATH EXHAUST FAN
3) PLAN CALLS FOR 200 AMP UPGRADE OVERHEAD. EXISTING SERVICE DOES NOT HAVE 8' CLEARANCE ROOF LINE
4) LAUNDRY 2" VTR NOT INSTALLED
5) NAIL PROTECT THROUGHOUT
6) APPROVAL FOR FRAMING PENDING ON ALL TRADES
07/16/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL TRADES
2) COMPLETE ALL HARDWARE TO AS BUILT
3) 6" ON CENTER EDGES 12" FIELD T-111 INSTALL ALL T-111 AND CALL 1025 FOR INSPECTION
07/10/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SPLICE 2 X 6 TO EXISTING 2 X 4 TAILS AT LAUNDRY ROOM 12" MINIMUM BEARING ON EXISTING WALL
2) DBL 2 X 6 HEADER ON EDGE REQUIRED AT BEDROOM EXTENSION
3) SUBMIT DETAIL OF SECTION AT ROOF IN BEDROOM FOR APPROVAL AT D.S.D.