Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/10/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/24/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) EXPOSE GAS LINE 2) OK TO SHEETROCK INTERIOR |
|
| 08/04/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 12-2 AND 14-2 WIRING MADE UP IN SAME BOX THROUGHOUT LAUNDRY 2) ROMEX CONNECTOR BATH EXHAUST FAN 3) PLAN CALLS FOR 200 AMP UPGRADE OVERHEAD. EXISTING SERVICE DOES NOT HAVE 8' CLEARANCE ROOF LINE 4) LAUNDRY 2" VTR NOT INSTALLED 5) NAIL PROTECT THROUGHOUT 6) APPROVAL FOR FRAMING PENDING ON ALL TRADES |
|
| 07/16/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES 2) COMPLETE ALL HARDWARE TO AS BUILT 3) 6" ON CENTER EDGES 12" FIELD T-111 INSTALL ALL T-111 AND CALL 1025 FOR INSPECTION |
|
| 07/10/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SPLICE 2 X 6 TO EXISTING 2 X 4 TAILS AT LAUNDRY ROOM 12" MINIMUM BEARING ON EXISTING WALL 2) DBL 2 X 6 HEADER ON EDGE REQUIRED AT BEDROOM EXTENSION 3) SUBMIT DETAIL OF SECTION AT ROOF IN BEDROOM FOR APPROVAL AT D.S.D. |