Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM00155

Parcel: 141353040

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM00155

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/12/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/10/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RETRO HOLDOWN NEEDED FOR OVERHEAD DOOR
2) NAIL PROTECT PLUMBING AND ELECTRIC AT SILL PLATES
03/06/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED LADDER TO ACCESS ROOF
2) HOLDOWN BETWEEN OVERHEAD GARAGE DOORS NAILED INTO FULL LENGTH STUD
3) ANCHOR BOLTS NEEDED
4) NAIL PROTECT WATER AND DWV AT SILL PLATE
5) 3 KING STUDS NEEDED AT EACH END OF OVER HEAD DOOR OPENING PER CHART ON S3.01
6) STOPPED INSPECTION-NOT READY