Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2010 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 02/02/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NEC OF CMU INFILL @ ACCESS POINT FROM 20' TO 24' 8" AFFE OK SPECIAL BY TERRACON |
|
| 01/29/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NEC CLOSURE OF ACCESS POINT OF CMU WALL FROM 12' TO 16' AFFE OK 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/28/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4TH LIFT OF CMU AT NEC OF GYM EXTERIOR WALL AT ACCESS CLOSURE FROM 12'-8" TO 16'-8" AFFE-OK TO GROUT |
|
| 01/27/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CLOSURE INFILL OF CMU WALL AT GYM N.E.C. FROM 8'-8" TO 12'-8" AFFE-OK 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/26/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT AT NEC CMU ACCESS CLOSURE FROM 4' TO 8'-8" AFFE-OK TO GROUT 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/25/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU ACCESS CLOSE UP AT N.E. CORNER OF GYM FROM 0' TO 4'-4" AFFE 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/22/2010 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/20/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALLS AT GYM MECH ROOM AND ELEVATOR SHAFT FROM 20'-8" TO 26' AFFE OK TO GROUT |
|
| 01/14/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALLS AT ELEVATOR AND MECH. FROM 16' TO 20' AFFE-OK TO GROUT 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/08/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GYM BLDG CMU WALLS @ ELEVATOR SHAFT, STAIRWELL & MECHANICAL ROOM, FROM 12' TO 16' AFFE. OK TO GROUT SPECIAL INSPECTION BY TERRACON |
|
| 01/07/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALL STEEL REINFORCEMENT AT GYM EAST AND WEST WALLS FROM 28' TO 30' AFFE, NORTH WALL FROM 24' TO 29'-7" AFFE AND WEST STAIRWELL WEST, SOUTH AND NORTH WALLS FROM 12' TO 14'-4" AFFE-OK TO GROUT 2) SPECIAL INSPECTION BY TERRACON |
|
| 01/06/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU MASONRY WALLS AT SOUTH, WEST AND EAST 0 TO 60' N OF S/E CORNER OF GYM BLDG FROM 24' TO 27'-4" AFFE OK TO GROUT-SPECIAL INSPECTION BY TERRACON |
|
| 01/04/2010 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU MASONRY WALLS AT ELEVATOR, STAIRWELL AND MECHANICAL ROOM FROM 8' TO 12' AFFE-OK TO GROUT |
|
| 12/30/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR GYM CMU WALLS ON WEST, NORTHEAST, & SOUTH SIDES FROM 20' TO 24' AFFE OK TO GROUT SPECIAL INSPECTION BY TERRACON |
|
| 12/29/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH, WEST AND NORTH CMU EXTERIOR GYM WALLS FROM 16' TO 20' AFFE OK TO GROUT 2) SPECIAL INSPECTED BY TERRACON |
|
| 12/21/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALL REINFORCEMENT AT EAST GYM WALL AND SOUTH WALL 0' TO 40' WEST OF SOUTHEAST CORNER FROM 16' TO 20' AFFE AND WEST AND NORTH WALLS AT GYM FROM 12' TO 16' OK TO GROUT-SPECIAL INSPECTION BY TERRACON |
|
| 12/17/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH CMU GYM WALL FROM 12' TO 16' AFFE OK TO GROUT AND EPOXY BARS AND BOLTS OK 2) SPECIAL INSPECTION BY TERRACON |
|
| 12/16/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) WEST CMU WALLS AND ELEVATOR, STORAGE, AND LOBBY TO 12' AFFE-SOUTH AND EAST ? GYM WALLS TO 16' AFFE-OK |
|
| 12/14/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS @ GYM SOUTH WALL FROM 8' TO 12' EAST WALL 0 - 60' N OF SEC FROM 8' TO 12' AFFE WEST WALL FROM 4' TO 8' AFFE & ELEVATOR, STAIRWELL & MECHANICAL ROOM WALLS FROM 4' TO 8' AFFE - OK TO GROUT SPECIAL INSPECTION BY TERRACON |
|
| 12/10/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) WEST CMU GYM EXTERIOR WALL AND INTERIOR CMU WALLS AT STAIR AND ELEVATOR FROM 0' TO 4' AFFE OK |
|
| 12/09/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) SOUTH CMU EXTERIOR WALL FROM 4' TO 8' AFFE, WEST EXTERIOR WALL FROM 0' TO 4' AFFE AND NORTH INTERIOR STORE ROOM CMU WALL FROM 0' TO 4' AFFE OK TO GROUT |
|
| 12/07/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU MASONRY WALLS OF GYM AT SOUTH AND EAST SIDES FROM 0' TO 4' AFFE OK TO GROUT |