Permit: T09CM00062

Parcel: 13414011A


Addresses:

401 S PRUDENCE RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
02/17/2010 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
02/02/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NEC OF CMU INFILL @ ACCESS POINT FROM 20' TO 24' 8" AFFE
OK SPECIAL BY TERRACON
01/29/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NEC CLOSURE OF ACCESS POINT OF CMU WALL FROM 12' TO 16' AFFE OK
2) SPECIAL INSPECTION BY TERRACON
01/28/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 4TH LIFT OF CMU AT NEC OF GYM EXTERIOR WALL AT ACCESS CLOSURE FROM 12'-8" TO 16'-8" AFFE-OK TO GROUT
01/27/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CLOSURE INFILL OF CMU WALL AT GYM N.E.C. FROM 8'-8" TO 12'-8" AFFE-OK
2) SPECIAL INSPECTION BY TERRACON
01/26/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 2ND LIFT AT NEC CMU ACCESS CLOSURE FROM 4' TO 8'-8" AFFE-OK TO GROUT
2) SPECIAL INSPECTION BY TERRACON
01/25/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU ACCESS CLOSE UP AT N.E. CORNER OF GYM FROM 0' TO 4'-4" AFFE
2) SPECIAL INSPECTION BY TERRACON
01/22/2010 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
01/20/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT GYM MECH ROOM AND ELEVATOR SHAFT FROM 20'-8" TO 26' AFFE OK TO GROUT
01/14/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT ELEVATOR AND MECH. FROM 16' TO 20' AFFE-OK TO GROUT
2) SPECIAL INSPECTION BY TERRACON
01/08/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GYM BLDG CMU WALLS @ ELEVATOR SHAFT, STAIRWELL & MECHANICAL ROOM, FROM 12' TO 16' AFFE.
OK TO GROUT
SPECIAL INSPECTION BY TERRACON
01/07/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALL STEEL REINFORCEMENT AT GYM EAST AND WEST WALLS FROM 28' TO 30' AFFE, NORTH WALL FROM 24' TO 29'-7" AFFE AND WEST STAIRWELL WEST, SOUTH AND NORTH WALLS FROM 12' TO 14'-4" AFFE-OK TO GROUT
2) SPECIAL INSPECTION BY TERRACON
01/06/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU MASONRY WALLS AT SOUTH, WEST AND EAST 0 TO 60' N OF S/E CORNER OF GYM BLDG FROM 24' TO 27'-4" AFFE OK TO GROUT-SPECIAL INSPECTION BY TERRACON
01/04/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU MASONRY WALLS AT ELEVATOR, STAIRWELL AND MECHANICAL ROOM FROM 8' TO 12' AFFE-OK TO GROUT
12/30/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EXTERIOR GYM CMU WALLS ON WEST, NORTHEAST, & SOUTH SIDES FROM 20' TO 24' AFFE OK TO GROUT
SPECIAL INSPECTION BY TERRACON
12/29/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH, WEST AND NORTH CMU EXTERIOR GYM WALLS FROM 16' TO 20' AFFE OK TO GROUT
2) SPECIAL INSPECTED BY TERRACON
12/21/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALL REINFORCEMENT AT EAST GYM WALL AND SOUTH WALL 0' TO 40' WEST OF SOUTHEAST CORNER FROM 16' TO 20' AFFE AND WEST AND NORTH WALLS AT GYM FROM 12' TO 16' OK TO GROUT-SPECIAL INSPECTION BY TERRACON
12/17/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH CMU GYM WALL FROM 12' TO 16' AFFE OK TO GROUT AND EPOXY BARS AND BOLTS OK
2) SPECIAL INSPECTION BY TERRACON
12/16/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST CMU WALLS AND ELEVATOR, STORAGE, AND LOBBY TO 12' AFFE-SOUTH AND EAST ? GYM WALLS TO 16' AFFE-OK
12/14/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ GYM
SOUTH WALL FROM 8' TO 12'
EAST WALL 0 - 60' N OF SEC FROM 8' TO 12' AFFE
WEST WALL FROM 4' TO 8' AFFE & ELEVATOR, STAIRWELL & MECHANICAL ROOM WALLS FROM 4' TO 8' AFFE - OK TO GROUT
SPECIAL INSPECTION BY TERRACON
12/10/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST CMU GYM EXTERIOR WALL AND INTERIOR CMU WALLS AT STAIR AND ELEVATOR FROM 0' TO 4' AFFE OK
12/09/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH CMU EXTERIOR WALL FROM 4' TO 8' AFFE, WEST EXTERIOR WALL FROM 0' TO 4' AFFE AND NORTH INTERIOR STORE ROOM CMU WALL FROM 0' TO 4' AFFE OK TO GROUT
12/07/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU MASONRY WALLS OF GYM AT SOUTH AND EAST SIDES FROM 0' TO 4' AFFE OK TO GROUT