Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T09CM00028
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2010 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/18/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 03/15/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) RECEPT EAST ROOM (EAST WALL NOT WIRED CORRECTLY (HOT/NEUTRAL REVERSED ? REAR UNIT 2) ALL COUNTER (KIT) RECEPTS NOT GFCI PROTECTED 3) ARIZ. BOX ON ROOF NOT WIRED CORRECTLY (120V RECEPT WITHOUT A NEUTRAL, GRD WIRE UNSECURED, CHECK WIRING, WILL TEST WHEN POWER TURNED ON TO BOX 4) EXTEND SEWER VENT 1'-0" ABOVE COOLER 5) WHY ARE ALL CIRCUITS 15 AMP #14 CU ? 6) STOPPED INSPECTION |
|
| 03/09/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLUMBING NOT COMPLETE 2) ARC FAULT PROTECTION REQUIRED IN BEDROOM OUTLETS, SWITCHES AND SMOKE ALARMS 3) PROVIDE ROOF ACCESS 4) $75.00 CHECK-#1083 |
|
| 02/25/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/02/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) SHEETROCK REAR UNIT OK |
|
| 01/29/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO SHEETROCK INSTALLED 11:10 AM |
|
| 01/20/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/05/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* OK TO OCCUPY FRONT UNIT REENFORCE FRONT PORCH BEAM AS ADVISED SEDIMENT TARP MISSING AT FURNACE GAS |
|
| 12/31/2009 | BUILDING - FINAL | Cancelled | IVRS - RI canceled | |
| 12/29/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OBVIOUS ELECTRICAL VIOLATIONS, BREACHED L.B. SCHEDULE 40 PVC NOT PROTECTED RAIN TIGHT FITTING REQUIRED EMT 2) HAVE LICENSED ELECTRICIAN/OWNER CONTACT ME AND HAVE LIC-PLUMBER CHECK ALL PLUMBING FOR COMPLIANCE 3) $75.00 OWED FOR THIS INSPECTION 4) HOUSE SHALL NOT BE OCCUPIED |
|
| 08/19/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEFT MESSAGE TO MEET AT 9:00 AM ON PHONE #603-1557 AT 7:42 AM FRONT UNIT: 1) EXPOSE ALL ELECTRICAL AND PLUMBING COVERED WITHOUT INSPECTIONS 2) HAVE LICENSED ELECTRICAL CONTRACTOR DO ALL WORK ON THIS PROPERTY FRONT AND REAR UNIT 3) ALL WORK SHALL BE DON BY LICENSED CONTRACTORS |
|
| 02/10/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |