Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PLUMBING
Permit Number - T09BU01629
Inspection Description - POOL/SPA PLUMBING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2009 | POOL/SPA PLUMBING | Approved | IVRS - Inspection :* | |
12/03/2009 | POOL/SPA PLUMBING | Not ready for Inspection | IVRS - Inspection :* | |
12/01/2009 | POOL/SPA PLUMBING | Partial Approval | IVRS - Inspection :* 1) PLAN ON SITE HAS NO CITY STAMP, ATMOSPHERIC RELIEF REQUIRED ON DRAIN LINE 2) IF NON-METALLIC CONDUIT USED FOR WET NICHE FIXTURE A CU. STRANDED #8 WIRE REQUIRED FROM FIXTURE CAN (EPOXY COATING ON CONNECTION BACK TO INSULATED J-BOX 3) PLEASE LEAVE LISTING GOR LIGHT FIXTURE 4) NOTE: SEE NOTES REF MOTOR CONTROLLER AND WIRING 5' FROM POOL EDGE 5) ALSO ENCLOSURE/BARRIER ARE METAL CLOSER THAN 5'-0" TO POOL EDGE NEEDS TO BE BONDED BACK TO MOTOR 6) NEED TEMP BARRIER AROUND POOL ASAP 7) 25 PSI H20 ON LINES |
|
11/25/2009 | POOL/SPA PLUMBING | Partial Approval | IVRS - Inspection :* 1) OK TO BACK FILL POOL ONLY 2) PROVIDE AIR TEST ALL ? |
|
11/04/2009 | POOL/SPA PLUMBING | Partial Approval | IVRS - Inspection :* 1) OK TO BURY 1 1/2" LINES AT BEND ONLY 2) KEEP JOINTS EXPOSED 3) NOT UNDER TEST AT THIS TIME |