Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T09BU01217
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/24/2009 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
08/21/2009 | POOL/SPA PRE-GUNITE | Not ready for Inspection | IVRS - Inspection :* 1) HOME RUN NOT INSTALLED YET 2) GAS LINE 1 1/4" SUPPLY TO HOUSE, 150' TOTAL LENGTH, 305.0 CFH THAT'S WITHOUT ANY OPTIONS, ADD 400,000 BTUS APPROX 700 CFH 1 1/4" PIPE AT 150'=324 CFH 7 2) WHAT IS THE REBAR (HORIZONTAL/VERTICAL) SPACING TO BE ? 3) CROSS SECTION OF 5' HIGH WATER FEATURE WALL IS IT RETAINING ? |