Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T09BU00987
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/2009 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
12/18/2009 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BROKEN CONDUIT TO EXHAUST FAN WITH WIRES EXPOSED STILL HAS NOT BEEN REPLACED |
|
11/04/2009 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) PERFORMED A CAPTURE AND CONTAINMENT TEST ON EXISTING HOOD 2) THE HOOD IS WORKING FINE 3) OK TO INSTALL AND TEST NEW ANSUL SYSTEM 4) PROVIDE A NEW CONDUIT TO EXHAUST FAN ON ROOF TO REPLACE THE BROKEN EXISTING CONDUIT |
|
09/10/2009 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
09/09/2009 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/09/2009 | MECHANICAL - FINAL | Denied | PROVIDE ACCESS TO ROOF. THE OPENING IN THE HOOD MUST EXTEND A MINIMUM OF 6" BEYOND THE COOLING SURFACE OF THE STOVE. |
|