Permit: T09BU00127

Parcel: 141280540

Inspection Status: Partial Approval

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
02/24/2009 POOL/SPA PRE-GUNITE Partial Approval IVRS - Inspection :*
1) OK 4 BOND WHIPS
2) REBAR SCHEDULE CALLS FOR #3 BAR AT 6" ON CENTER VERT.
3) CALL FROM STEEL ENGINEER WILL SUPPY A LETTER OF CLARIFICATION INCREASING VERT. SPACING TO 12" ON CENTER
4) WILL SIGN OFF WHEN LETTER IS OK'D
5) GUNITE AT YOUR OWN RISK
6) ATMOSPHERIC RELIEF NOT REQUIRED
02/23/2009 POOL/SPA PRE-GUNITE Not ready for Inspection IVRS - Inspection :*
SEE LAST INSP.
02/20/2009 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NEED REBAR SCHEDULE
DEFINED AS FAR AS 5'0" DEPTH
6" O.C. REBAR