Permit: T08PL01860

Parcel: 10603054B


Addresses:

3250 N STONE AV #10

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/10/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
1. PLEASE NOTE HOOKING TWO WATER FLEXES TOGETHER IS NOT AN ACCEPTED PRACTICE
2. ALL HOSE BIBS REQUIRE AVB's
3. YOU WILL BE FAILED FOR THIS IN THE FUTURE
02/09/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NOBODY HOME
NO ACCESS
12/24/2008 PLUMBING - FINAL Denied 1. PROVIDE A WEATHERPROOF ENCLOSURE THAT IS WEATHER PROOF FOR HEATER
2. PROVIDE SEDIMENT TRAP FOR GAS ENTRY INTO WATER HEATER
3. VENT TO BE DOUBLE WALL IN UNCONDITIONED SPACE