Permit: T08PL01820

Parcel: 110140170

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01820

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
01/06/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
TPR DRAIN MAY NOT GO UP HILL AND MAY NOT CONNECT DIRECTLY TO AND SANITARY DRAIN OR VENT PIPE, IT MUST HAVE AN AIR GAP TO SEPARATE YOUR POTABLE WATER SYSTEM AND SANITARY SEWER SYSTEMS. A FLEX CONNECTOR IS NOT APPROVED FOR TPR DRAIN PIPING. YOU MAY ALSO TERMINATE TPR DRAIN TO EXTERIOR, USE APPROVED MATERIALS
12/30/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*