Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08PL01818

Parcel: 113042890


Addresses:

1020 E HALCYON RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS TO WH, FURNACE AND RANGE ONLY
12/16/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE PLAN, CHECK SIZING.
ALL OUTLETS MUST BE SHOWN
2. CORRECT WH, T&P AND VENT
3. SUPPORT PIPING
4. PROVIDE CLEARANCE AT PARAPET
5. BONDING
6. SEDIMENT TRAP AT FURNACE