Inspection Status: Partial Approval
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. OK FOR GAS; BACKFILL PIPING W/CLEAN FILL 2. SECURE WH VENT WITH 3 SHEETMETAL SCREWS @ EACH JOINT 3. PROVIDE MATERIALS APPROVED FOR USE WITH HOT WATER FOR TPR DRAIN AND TERMINATE WITHOUT THREADS 4. RECALL FOR INSPECTION |
|
| 12/12/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - THE MIN. CODE STANDARDS REQUIRE THE FOLLOWING - CORRECT VENT; VENT CONNECTOR IS NOT EVEN CONNECTED TO THE B-VENT. - INSERT CONNECTOR INTO B-VENT FITTING - T&P SHALL BE OF APPROVED MATERIALS; FULL SIZE & OPERATIONAL. REF. 2006 UNIFORM PLUMBING CODE - ALSO, WRAP PIPE MACHINE CLAMPING VISE MARKS BELOW GRADE |
|
| 12/11/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. EXTEND 1" TO FIRST BRANCH CONN. (INSTALL A FULL SIZED TEE) 2. CORRECT WATER HEATER VENT AND TEMPERATURE AND PRESSURE RELIEF VALVE TERMINATIONS 3. WRAP ALL TOOL MARKS BELOW GRADE AND SHADE PIPING WITH CLEANFILL |