Permit: T08PL01755

Parcel: 10606006A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01755

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
REQUIRE TEN POUND TEST ON GAS SYSTEM
*REINSPECTED
OK FOR GAS
UCC LEFT AT METER
SW GAS @ 889-1888
12/11/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 2/10TH PSI DROP IN 5 MIN. MUST HOLD STEADY FOR 15 MIN.
2. SUGGEST REPLACING VALVE AT FURNACE
3. ALSO, OK TO TEST W/APPLIANCE VALVES CLOSED
4. CORRECT COMBUSTION AIR OPENING AT WH