Permit: T08PL01751

Parcel: 135031100


Addresses:

6550 E CALLE CASTOR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
12/12/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ATTACH GROUNDING WIRE TO SERVICE PIPING WITH MINIMUM 10' IN GROUND COPPER PIPING
2. EXPOSED PEX AT KITCHEN SUBJECT TO DAMAGE SHALL BE PROTECTED OR PIPED IN COPPER
3. ADD NEW WATER HEATER TO PERMIT
4. PROVIDE WATER HAMMER ARRESTORS AT WASHING MACHINE
5. MAKE VENT CONNECTOR UP CORRECTLY AT DRAFT HOOD AND PROVIDE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES THRU ROOF WITH DOUBLE WALL VENT PIPING WITH CORRECT ROOF JACK AND CORRECT VENT CAP (VENT IS CRUSHED)