Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL01725
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/17/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD @ METER SW GAS 889-1888 |
|
12/16/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE APPROVED VENT CONNECTOR MATERIAL FOR WATER HEATER VENT WITH 3-FASTENERS AT EACH JOINT. 2. PROVIDE WATER HEATER T&P DRAIN (GRAVITY) WITH 90 DEG. DOWN AT TERMINATION (CPVC) 3. VALVES TO BE BEFORE FLEX PIPING TO APPLIANCE 4. PROVIDE BONDING OF BLD. GAS PIPING RETEST AND CALL IN |