Permit: T08PL01710

Parcel: 133385030

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01710

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/04/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS TO DECORATIVE GAS FIREPLACE W/STUB FOR FUTURE APPLIANCE AT BUILDING EXTERIOR PER APPROVED PLAN.
12/03/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11.5
CLAMP RISER NEAR TOP, SEAL WALL PENETRATIONS
REDUCER BUSHINGS MAY ONLY BE USED IN EXPOSED LOCATIONS -- USE A REDUCING COUPLING
11/28/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE PIPING W/APPROVED PIPE CLAMPS
2. OFFSET PIPING AROUND WATER AND CONDUIT
3. DO NOT BEND OR STRAIN PIPING
4. DECORATIVE APPLIANCE ONLY DOES NOT REQUIRE LOG LIGHTER VALVE, BUT HARD PIPE INTO FIREPLACE; A FLEX MAY NOT BE CONCEALED.
5. ADDITIONAL GAS OUTLET FOR FUTURE SHALL BE IDENTIFIED ON A CITY APPROVED PLAN
6. HAVE TEST ON SYSTEM PRIOR TO INSPECTION