Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL01710
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS TO DECORATIVE GAS FIREPLACE W/STUB FOR FUTURE APPLIANCE AT BUILDING EXTERIOR PER APPROVED PLAN. |
|
12/03/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 11.5 CLAMP RISER NEAR TOP, SEAL WALL PENETRATIONS REDUCER BUSHINGS MAY ONLY BE USED IN EXPOSED LOCATIONS -- USE A REDUCING COUPLING |
|
11/28/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SECURE PIPING W/APPROVED PIPE CLAMPS 2. OFFSET PIPING AROUND WATER AND CONDUIT 3. DO NOT BEND OR STRAIN PIPING 4. DECORATIVE APPLIANCE ONLY DOES NOT REQUIRE LOG LIGHTER VALVE, BUT HARD PIPE INTO FIREPLACE; A FLEX MAY NOT BE CONCEALED. 5. ADDITIONAL GAS OUTLET FOR FUTURE SHALL BE IDENTIFIED ON A CITY APPROVED PLAN 6. HAVE TEST ON SYSTEM PRIOR TO INSPECTION |