Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T08PL01682
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2009 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 08/04/2009 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1) NOT UNDER TEST 2) ROCKS IN DITCH 3) NOT CONTINOUSLY SUPPORTED |
|
| 07/22/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) UNITS #7,9,43,44,46,30,31,32,29,28,64,63,62,61 AND CLUB HOUSE |
|
| 07/02/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) UNITS #33, 34, 36, 22, 1, 2, 3, 8, 6, 5 & 4 OK TO COVER |
|
| 06/30/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* UNITS: #10,11,19,59,58,57,56,55,54,53,52,51,50,20,21,23,25,26,42,40,39,38 AND 37 |
|
| 06/29/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) UNCOVER ALL WORK COVERED WITHOUT INSPECTION 2) 14,35,15,16,17 & 18 ARE OK TO COVER 3) NON METALLIC UTILITIES REQUIRE TRACER |
|
| 06/26/2009 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/20/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1. 2006 UPC INSTALLATION STANDARD TWENTY SECTIONS 2.7.9 AND 2.7.12.1 TRANSITION FITTINGS 2. SUPPORT UNDER FLOOR HORIZONTAL PIPING |
|
| 04/30/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | RV CONNECTIONS MADE OK | |
| 04/28/2009 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* SEE E14 APPENDIX 2006 UPC REQUIRE 3/4" SUPPLY TO MOBILE HOME. A HOSE BIB DOES NOT HAVE 3/4" THRUWAYS NOR IS A HOSE CONNECTION THE ACCEPTABLE METHOD OF MOBILE HOME CONNECTION |
|
| 04/23/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1. UNDERGROUND MAIN COMPLETE MOST BRANCHES RUN OUT TO METER BOX THE REST IS CAPPED 2. OK TO COVER |
|
| 04/15/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* UNDERGROUND SCH80 PVC MAIN WITH BRANCHES OK TO COVER ALONG AGAVE ST. |
|
| 04/14/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) N/S MAIN FROM 1ST TEE ON E/W MAIN TO "A CAVE RD." WITH TEST OK 2) DISCUSSED STERIALIZATION REQUIREMENTS WITH STAT PLUMBING |
|
| 04/07/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1-602-531-9792 MAINS AND BRANCHES IN "ORGAN PIPE ROAD" PER DRAWING W/INITIALS |
|
| 04/01/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 3" SCH 80 PVC FROM 1ST ZONE VALVE EAST TO NEXT ZONE AS INITIALED ON PLAN - WITH BRANCHES OK TO COVER NO M.H. CONNECTIONS MADE AT THIS TIME |
|
| 03/27/2009 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* SCH80 PVC WITH TRACER WIRE FROM METER THRU RPPBP TO FIRST ZONE VALVES, WITH BRANCHES TO ISOLATION VALVES OK TO COVER |
|
| 03/26/2009 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* PROVIDE BLUE TRACER WIRE AND ATTACH TO PIPE 8' O.C. TUCSON WATER REQUIRES A BACKFLOW PREVENTION ASSEM. INSTALLATION PERMIT FOR REPLACEMENT RP |