Permit: T08PL01682

Parcel: 10612031C


Addresses:

3426 N ROMERO RD

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
08/07/2009 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
08/04/2009 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
1) NOT UNDER TEST
2) ROCKS IN DITCH
3) NOT CONTINOUSLY SUPPORTED
07/22/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) UNITS #7,9,43,44,46,30,31,32,29,28,64,63,62,61 AND CLUB HOUSE
07/02/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) UNITS #33, 34, 36, 22, 1, 2, 3, 8, 6, 5 & 4 OK TO COVER
06/30/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
UNITS: #10,11,19,59,58,57,56,55,54,53,52,51,50,20,21,23,25,26,42,40,39,38 AND 37
06/29/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) UNCOVER ALL WORK COVERED WITHOUT INSPECTION 2) 14,35,15,16,17 & 18 ARE OK TO COVER
3) NON METALLIC UTILITIES REQUIRE TRACER
06/26/2009 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/20/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1. 2006 UPC INSTALLATION STANDARD TWENTY SECTIONS 2.7.9 AND 2.7.12.1 TRANSITION FITTINGS
2. SUPPORT UNDER FLOOR HORIZONTAL PIPING
04/30/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval RV CONNECTIONS MADE OK
04/28/2009 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
SEE E14 APPENDIX 2006 UPC REQUIRE 3/4" SUPPLY TO MOBILE HOME. A HOSE BIB DOES NOT HAVE 3/4" THRUWAYS NOR IS A HOSE CONNECTION THE ACCEPTABLE METHOD OF MOBILE HOME CONNECTION
04/23/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1. UNDERGROUND MAIN COMPLETE
MOST BRANCHES RUN OUT TO METER BOX
THE REST IS CAPPED
2. OK TO COVER
04/15/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
UNDERGROUND SCH80 PVC MAIN WITH BRANCHES
OK TO COVER ALONG AGAVE ST.
04/14/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) N/S MAIN FROM 1ST TEE ON E/W MAIN TO "A CAVE RD." WITH TEST OK
2) DISCUSSED STERIALIZATION REQUIREMENTS WITH STAT PLUMBING
04/07/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1-602-531-9792

MAINS AND BRANCHES IN "ORGAN PIPE ROAD"
PER DRAWING W/INITIALS
04/01/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
3" SCH 80 PVC FROM 1ST ZONE VALVE EAST TO NEXT ZONE AS INITIALED ON PLAN - WITH BRANCHES OK TO COVER
NO M.H. CONNECTIONS MADE AT THIS TIME
03/27/2009 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
SCH80 PVC WITH TRACER WIRE FROM METER THRU RPPBP TO FIRST ZONE VALVES, WITH BRANCHES TO ISOLATION VALVES OK TO COVER
03/26/2009 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
PROVIDE BLUE TRACER WIRE AND ATTACH TO PIPE 8' O.C.
TUCSON WATER REQUIRES A BACKFLOW PREVENTION ASSEM.
INSTALLATION PERMIT FOR REPLACEMENT RP