Permit: T08PL01680

Parcel: 134211580


Addresses:

7043 E HAYNE PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/20/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD AT METER
11/19/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
THIS IS A REPIPE
1. PROVIDE FULL SIZE SCOTCH COATED PIPING AT BOTH RISER LOCATIONS
2. PRIME THEN TAPE ALL TOOL MARKS AND FITTINGS
TO 6" ABOVE GROUND TO ACHIEVE 40 MIL THICKNESS ON PIPE WRAP
3. PROVIDE AN APPROVED BUILDING SHUT OFF VALVE AT ENTRY TO BUILDING ON GAS PIPING
4. PROVIDE CORRECT VENT PIPING AT WATER HEATER REMOVE ALL TAPE & PROVIDE FASTENERS FOR VENT JOINTS
5. REINSTALL BONDING CLAMP AT WATER HEATER GAS PIPING
6. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE AND WATER HEATER
7. PROVIDE CORRECT SIZE FLEX TO FURNACE FOR 100,000 BTU DEMAND