Permit: T08PL01669

Parcel: 127111060


Addresses:

6060 E 2ND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/10/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
06/01/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. IMPROPER VENTING
2. IMPROPER T&P TERMINATION
3. PROVIDE ELECTRICAL BONDING
4. NO APPROVED GAS CONNECTOR ON SITE FOR WH
5. OWNER WAS ARGUMENTATIVE, HOSTILE AND THREATENED LEGAL ACTION
05/08/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CAP UNUSED PIPING (OR SEAL) PSI AT 5 UPON ARRIVAL
10 PSI REQUIRED
REMOVE FUTURE TEE CONN. OR SHOW IT ON PLAN
PROVIDE APPROVED PIPE SUPPORTS
INSTALL SEDIMENT TRAPS 1211.7.3
CORRECT WH SUPPORTING STRUCTURE AND VENTING (WATER HEATER INSTALLED W/OUT PERMIT)
TYPE B VENT SHALL ORIGINATE WITHIN ROOM
DRAFT COLLAR REQUIRED
SEE UPC SECTIONS (2006) 510.3.1, 510.4.1, 502.9 AND 101.6 ALSO, 101.4 AND 503, 102.3.2

NOTE: HOME OWNER THREATENED LEGAL ACTION!
05/01/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
9:35 NO ACCESS
PLEASE HAVE A TEST ON YOUR ENTIRE GAS SYSTEM AND AN ADULT PRESENT TO PROVIDE ACCESS TO ENTIRE GAS SYSTEM AT REINSPECTION. THIS IS NOT A COMPLETE LIST.