Permit: T08PL01669

Parcel: 127111060


Addresses:

6060 E 2ND ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
08/10/2009 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
07/09/2009 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection :*
1) SINGLE WALL VENT CONNECTOR MAY NOT PENETRATE CEILING SPACE AND REQUIRES 6" OF CLEARANCE FROM COMBUSTIBLES
2) B-VENT MAY NOT CHANGE BACK TO SINGLE WALL
3) B-VENT SHALL BE INSTALLED IN CORRECT DIRECTION OF FLOW
4) WOOD WH STAND DOES NOT COMPLY WITH IBC BLDG CODES 2301.2 AND 2305.1.2.1
5) PROVIDE A LISTED APPROVED STAND, SET WH ON FLOOR OR BUILD TO IBC CODES
6) IF WOOD IS USED INSTALL A PAN UNDER HEATER
7) CAP FUTURE ? AND PROVIDE TEST
8) INSTALL GAUGE AT METER LOCATION
9) GROUNDING IS NOT ELECTRICAL BONDING
10) YOU MAY BOND WATER TO GAS OR BOND TO PANEL
11) CONTINUED DENIED INSPECTIONS MAY RESULT IN RE-INSPECTION FEE
07/06/2009 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection :*
1) CALLED 747-0423 NUMBER NOT WORKING
2) NO ONE AT HOME UNABLE TO DO INSPECTION
05/08/2009 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection :*
05/01/2009 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :