Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T08PL01668
Inspection Description - SITE - SEWER
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2010 | SITE - SEWER | Approved | IVRS - Inspection :* | |
| 08/05/2010 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 02/11/2010 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1. NEED AUTHORIZATION TO DISCHARGE FROM PC DEQ 2. WOOD TERMINATION OR TRACER WIRES IN MANHOLES WITH CORRECT TERMINATION OF MANHOLE COVERS TO PIMA COUNTY & CITY OF TUCSON STANDARDS |
|
| 02/19/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* VACUUM TEST MANHOLE #12, 13, 14 OK |
|
| 02/18/2009 | SITE - SEWER | Partial Approval | IVRS - Inspection :* AIR TESTING FROM MANHOLE: #11 TO #12 8" SDR 35 PIPING OK #12 TO #13 OK 8" SDR 35 PIPING OK #12 TO #14 OK 8" SDR 35 PIPING OK MANDRILL FROM MANHOLE #11 TO 12 OK; 12 TO 13 OK; 12 TO 14 OK MIRROR OF SAME OK |
|
| 12/30/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) BEDDING, LAYING SHADING, TRAILER 8 SDR 35 FROM MANHOLE #12 TO 14. BASES POURED MANHOLE #12, 13 & 14 |
|
| 12/23/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 12/19/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* BEDDING, LAYING, TRACER FROM EXISTING MANHOLE #11 8" SDR35 TO NEW MANHOLE #12, TO NEW MANHOLE #13 TESTING AT LATER DATE |